Does the Er rF error code show on the display? |
Unplug the refrigerator and check CONNECTOR 4. Check for bent pins and broken wires, then reconnect it and power up the refrigerator. |
Power up the refrigerator and enter TEST 1 MODE.
Read the voltage across PIN 3 (BL/WH) and PIN 4 (GY). It should be 12 ~ 16 VDC. If not, replace the MAIN BOARD. |
Still in TEST 1 MODE, check the top vents of the MULTI-DUCT for air flow. |
Still in TEST 1 MODE, if there is no air flow, remove the MULTI-DUCT and check the fan motor. Check the connector and make sure the motor turns. Replace the motor if it is locked. |
Still in TEST 1 MODE, check the voltage across PIN 4 (GY) and PIN 5 (YL/BK) of CONNECTOR 4. It should be 1 ~ 4 VDC. If not, replace the MAIN BOARD. |