Does the display show Er SS? |
Check the connector on the MAIN BOARD and at the SENSOR CONNECTION. Unplug and reconnect them. Check for bent pins and broken wires. |
Disconnect the power to protect the microprocessor. Measure the resistane across PIN 10 and PIN 11. (WH/RD and WH/RD wires) If it is not between 6 and 300 K ohms, replace the pantry sensor. |
Remove the pantry drawer to provide access to the sensor connector. |
Read the resistance across PIN 3 and PIN 6 of the connector. (BR and BR wires) If it is not between 6 and 300 K ohms, replace the pantry sensor.
Restore power to the refrigerator. Press FREEZER and ICE+PLUS at the same time. If the Er SS code appears,replace the MAIN BOARD. |
Questions? Comments! Concerns? Report an error?
Let us know!
An e-mail should solve the problem.