Check the connectors at the DISPLAY BOARD and inside the ICEMAKER COMPARTMENT. |
Disconnect CONNECTOR 101 and measure the resistance across pins 5 and 6. (BLUE and BLUE wires.) The resistance should be between 1.4 and 120 K ohms. If not, replace the sensor in the icemaker compartment. |
Inside the idemaker compartment, unplug the small blue connector and measure the resistance across pins 1 and 2. (BLUE and BLUE wires.) The resistance should be between 1.4 and 120 K ohms. If not, replace the sensor in the icemaker compartment.
Reconnect the power and turn the refrigerator on. Press FREEZER and ICE+PLUS at the same time. If the ER IS error message appears, replace the MAIN BOARD. |
Questions? Comments! Concerns? Report an error?
Let us know!
An e-mail should solve the problem.