Condensor Fan Error - Er CF Online Training Manual for LG Products - Er CF - Condenser Fan Error      

cf_1
Schematic for Condenser Fan.

cf_2
Is Er CF displayed?

cf_3
Check the connection on the Main Board.

cf_4
Reset the refrigerator and start TEST MODE 1. Is the voltage between pins 12 and 13 (CON 4) 10~16 VDC? If not, replace the Main Board. (Pin 12 is the pink wire; pin 13 is WHITE and RED.)

cf_5
Does the fan turn in Test Mode? Check the voltage at the fan connector. If not between 10~16 VDC, replace the fan motor.

cf_7
Check the condenser fan to see that it is turning. If it is between 10 and 16 VDC but the fan is not running or locked, replace the fan.

cf_6
Check the feedback voltage across pins 13 and 14 of CON 4. It should be between 1 and 4 VDC. with the fan running. If not, replace the Main Board. (Pin 13 is WHITE and RED; pin 14 is Sky Blue.)