Measure when cool. (room temperature of 77° F / 25° C) Normal resistance is 14 ohms ± 10%. Replace if not within this spec. |
Measure when cool. (room temperature of 77° F / 25° C) Normal resistance is 17 ohms ± 10%. Replace if not within this spec. |
Measure when cool. (room temperature of 77° F / 25° C) Normal resistance is 80 ohms ± 10%. Replace if not within this spec. |
Measure when cool. (room temperature of 77° F / 25° C) Normal resistance is 95 ohms ± 10%. Replace if not within this spec. |
Disconnect the wires from the cooktop element. Test between the element terminal and terminal 1A. Normal resistance is 46 ohms ± 10%. |
Test between limiter terminals 1A and 2A. Normal resistance is 0 ohms. (Continuity) |
Test between limiter terminals 1B and 2B. Below 150° F = infinite resistance (open) Above 150° F = continuity (0 ohms) Replace the element if any test shows the element to be out of spec. |
Disconnect the wires from the cooktop element. Test between terminals E1 and E2. Normal resistance is 33 ohms ± 10%. Test between terminals E3 and E4. Normal resistance is 70 ohms ± 10%. Test between terminals E5 and E6. Normal resistance is 31 ohms ± 10%. Replace the element if any test shows the element to be out of spec. |
Test between terminals 1A and 2A on both front and rear elements. Normal resistance is 0 ohms (continuity). |
Test between limiter terminals 1B and 2B on both front and rear elements. Below 150° F = infinite resistance (open) Above 150° F = continuity (0 ohms) Replace the element if any test shows the element to be out of spec. |
Disconnect the wires from the cooktop element. Test between the element terminal and terminal 1A. |
Test between the limiter terminals 1A and 2A. Normal resistance is less than 0.5 ohms. Replace the element if any test shows the element to be out of spec. |
Test between terminals 1A and E3. Normal resistance is 70.5 ohms ± 10% (OUTER 800 watts @ 240 VAC) Test between terminals 1A and E2. Normal resistance is 50.0 ohms ± 10%. (MIDDLE 1,100 watts @ 240 VAC) Test between terminals 1A and E1. Normal resistance is 49.5 ohms ± 10%. (INNER 1,100 watts @ 240 VAC) |
Test between limiter terminals 1A and 2A. Normal resistance is 0 ohms. (continuity) |
Test between limiter terminals 1B and 2B. Below 150° F = infinite resistance (open) Above 150° F = continuity (0 ohms) Replace the element if any test shows the element to be out of spec. |